Retail Store Layout and Aisle Width Calculator
Enter the shop floor area and the shelving depth. See the occupant load, exits and doors, the aisle widths the Fire Code asks for, the accessible route minimums and a quick fixture run estimate.
Preliminary planning figure only. The architect, the fire protection engineer and the permit set govern the layout and the means of egress.
0 persons
| Item | Result |
|---|
Ardenvale builds and renovates retail stores, shopping centre units and storefronts across the Greater Toronto Area, from demolition and framing to finishes and fixtures coordination.
Retail store construction · Retail renovation · Shopping centre construction
Get a quote for your retail store build-outUse this tool from any AI assistant
Paste this link into ChatGPT, Claude, Gemini, Copilot, Perplexity or any AI assistant and ask it to read the result:
Change the numbers in the link to match your project. All tools for AI assistants.
Sources and assumptions
- Last checked 2026-11-09, against the 2024 Building Code Compendium and the e-Laws text of the Fire Code.
- 2024 Ontario Building Code (O. Reg. 163/24), Division B, Part 3 Article 3.1.17.1 and Table 3.1.17.1; Sentences 3.4.2.1.(1) and (2), 3.4.2.5.(1), 3.4.3.2.(1), (7) and (8); 3.8.1.3.(1) and (4); 3.8.3.3.(1); Article 3.3.1.10 (aisles follow the Fire Code). Projects permitted under the earlier Ontario Regulation 332/12 may be subject to that version.
- Ontario Fire Code (O. Reg. 213/07), Division B, Sentence 2.7.1.1 Aisles in a mercantile occupancy: at least 1,100 mm clear to each required exit; a subsidiary aisle with one direction of travel at least 900 mm clear and not over 7.5 m long.
- Values used Occupant load: 3.70 m² per person (first storey and upper storey with a principal entrance from a pedestrian thoroughfare or parking area), 5.60 m² per person (other storeys). Exit width: 6.1 mm per person for doorways. Travel distance: 45 m sprinklered throughout, 30 m otherwise.
Building out a new store?
Send us the plans or a short description. We will arrange a site review and return a clear written quote.
Ardenvale builds and renovates retail stores, shopping centre units and storefronts across the Greater Toronto Area, from demolition and framing to finishes and fixtures coordination. Retail store construction · Retail renovation · Shopping centre construction
Frequently asked questions
How many people does a shop floor hold?
Table 3.1.17.1 gives 3.70 square metres per person for mercantile space in a basement or first storey, and for a second storey with a principal entrance from a pedestrian thoroughfare or parking area, and 5.60 square metres per person for other storeys. The occupant load then sets the exit width and the number of washroom fixtures.
How wide must retail aisles be?
The Building Code leaves aisles to the Fire Code. Sentence 2.7.1.1.(2) of the Ontario Fire Code requires that every required exit in a mercantile floor area that is not divided into suites served by corridors, and that needs more than one exit, be served by an aisle at least 1,100 mm clear that offers a choice of two directions to reach an exit. A subsidiary aisle with a single direction of travel may be 900 mm clear and up to 7.5 m long (Sentence 2.7.1.1.(3)).
What about wheelchair access through the store?
Sentence 3.8.1.3.(1) requires a barrier-free path of travel to have an unobstructed width of at least 1,100 mm. A path narrower than 1,600 mm needs an unobstructed space 1,800 mm by 1,800 mm at least every 30 m (Sentence 3.8.1.3.(4)). Doorways on the path need 850 mm clear (Sentence 3.8.3.3.(1)).
How many exits does a store need?
At least two (Sentence 3.4.2.1.(1)), except for small floor areas in buildings of not more than two storeys with an occupant load of not more than 60 that meet Table 3.4.2.1.-A or -B (Sentence 3.4.2.1.(2)). The tool tests that when you enter the travel distance.
Is the fixture run estimate a Code requirement?
No. It is planning arithmetic: how many parallel fixture runs of the depth you enter fit across the store width with an aisle between each and along each end. It helps compare layouts. The architect confirms the real plan, including checkouts, entrances and accessible fixtures.
Does this replace a test fit?
No. It sets the Code-driven numbers to design around. A test fit by the architect or the retail fixture designer settles the layout.
Cite this tool