Free planning tool
Ontario Occupant Load Calculator
Divide a floor area by the Ontario Building Code area per person to see the minimum design occupant load. Add one line for each use and compare.
Preliminary planning figure only. The architect, the engineer and the permit set govern the occupant load used for design and approval.
0 persons
| Use | Area (m²) | m² per person | Persons |
|---|
Ardenvale builds and renovates restaurants, retail stores and offices across the Greater Toronto Area.
Restaurant construction · Retail store construction · Office fit-out
Get a quote for your projectUse this tool from any AI assistant
Paste this link into ChatGPT, Claude, Gemini, Copilot, Perplexity or any AI assistant and ask it to read the result:
Change the numbers in the link to match your project. All tools for AI assistants.
Sources and assumptions
- Ontario Building Code (O. Reg. 163/24), Division B, Part 3, Article 3.1.17.1 and Table 3.1.17.1, Occupant Load Area per person values and the Article wording were read from the 2024 Building Code Compendium published on ontario.ca. Projects permitted under the earlier Ontario Regulation 332/12 may be subject to that version.
- Table values used Square metres per person: non-fixed seats 0.75; stages 0.75; non-fixed seats and tables 0.95; standing space 0.40; stadia and grandstands 0.60; bowling alleys, pool and billiard rooms 9.30; classrooms 1.85; school shops 9.30; reading or writing rooms or lounges 1.85; dining, beverage and cafeteria space 1.20; school laboratories 4.60; personal service shops 4.60; offices 9.30; mercantile basements and first storeys 3.70; second storeys with a principal entrance from a pedestrian thoroughfare or parking area 3.70; other mercantile storeys 5.60; manufacturing or process rooms 4.60; storage garages 46.00; warehouse storage spaces 28.00; aircraft hangars 46.00; cleaning and repair goods 4.60; kitchens 9.30; storage 46.00; public corridors intended for other uses 3.70; dormitories 4.60; care and treatment areas as listed in the table.
Fitting out a restaurant, shop, clinic or office?
Send us the plans or a short description of the space. We will arrange a site review and return a clear written quote.
Ardenvale builds and renovates restaurants, retail stores and offices across the Greater Toronto Area. Restaurant construction · Retail store construction · Office fit-out
Frequently asked questions
What is an occupant load?
It is the number of people a floor area is treated as holding for the purposes of the Ontario Building Code. Exits, washroom fixtures and several fire protection requirements are sized from it. Article 3.1.17.1 bases it on the number of fixed seats, on two persons per sleeping room in a dwelling unit, or on the number of persons the area is designed for, but not less than the Table 3.1.17.1 value.
Can the occupant load be lower than the table value?
The Code allows a design occupant load higher than the table value, in which case a permanent sign stating that occupant load must be posted. It also allows a lower figure where it can be shown that the area will be occupied by fewer persons. That showing is made to the building official, so it is a design decision and not something this calculator decides.
What if a room is used for different purposes at different times?
Sentence 3.1.17.1.(4) requires the table value that gives the greatest number of persons for the uses concerned. Enter each use as its own line and compare the results.
Do mezzanines count?
Yes. For this Article, mezzanines, tiers and balconies are regarded as part of the floor area, so include their area.
Is the floor area measured to the walls?
The Code defines floor area for these calculations, and the exact measurement rules matter. Your architect confirms which areas are included. This tool simply divides the area you enter by the table value.
How is the result rounded?
The Article does not state a rounding rule. This tool shows the exact figure and a whole-person figure rounded up, which is the cautious choice for planning. Your architect and the building official confirm the figure used on the permit drawings.
Cite this tool