Restaurant Seating and Washroom Requirement
Enter the dining area and the seats you plan. See the occupant load, the minimum patron and employee water closets and lavatories, and how many barrier-free stalls and universal washrooms to plan for.
Preliminary planning figure only. The architect, the public health unit, the building official and the permit set govern the seat count and the fixture count.
0 persons
| Fixture | Male | Female |
|---|
Ardenvale builds and renovates restaurants, fast casual restaurants and coffee shops across the Greater Toronto Area, including kitchens, dining rooms and washrooms.
Restaurant construction · Restaurant renovation · Fast casual restaurants · Coffee shops
Get a quote for your restaurant build or renovationUse this tool from any AI assistant
Paste this link into ChatGPT, Claude, Gemini, Copilot, Perplexity or any AI assistant and ask it to read the result:
Change the numbers in the link to match your project. All tools for AI assistants.
Sources and assumptions
- Last checked 2026-11-09, against the 2024 Building Code Compendium on ontario.ca.
- 2024 Ontario Building Code (O. Reg. 163/24), Division B, Part 3 Article 3.1.17.1 and Table 3.1.17.1 (occupant load); Articles 3.7.4.2 and 3.7.4.3 with Tables 3.7.4.3.-D, -E and -F (plumbing fixtures for restaurants); Article 3.8.2.3 with Tables 3.8.2.3.-A and -B (barrier-free washrooms). Projects permitted under the earlier Ontario Regulation 332/12 may be subject to that version.
- Table 3.7.4.3.-D values used (water closets for each sex) 1 to 20 persons, 1; 21 to 70, 2; 71 to 105, 3; 106 to 135, 4; 136 to 165, 5; 166 to 195, 6; 196 to 225, 7; 226 to 275, 8; 276 to 325, 9; 326 to 375, 10; 376 to 425, 11; over 425, 12 plus 1 for each additional 50 persons. A partial increment is rounded up.
- Table 3.7.4.3.-E values used (alcoholic beverage establishments with limited or no food service) 1 to 50 persons, 2; 51 to 70, 3; 71 to 90, 4; 91 to 110, 5; 111 to 140, 6; 141 to 180, 7; 181 to 220, 8; 221 to 260, 9. The published wording above 260 persons is unclear, so this tool gives no count there.
- Table 3.7.4.3.-F values used (employees, restaurants with more than 40 seats) 1 to 9 employees of each sex, 1; 10 to 24, 2; 25 to 49, 3; 50 to 74, 4; 75 to 100, 5; over 100, 6 plus 1 for each additional 30. Each count applies to water closets and to lavatories.
Opening or renovating a restaurant?
Send us the plans or a short description. We will arrange a site review and return a clear written quote.
Ardenvale builds and renovates restaurants, fast casual restaurants and coffee shops across the Greater Toronto Area, including kitchens, dining rooms and washrooms. Restaurant construction · Restaurant renovation · Fast casual restaurants · Coffee shops
Frequently asked questions
How many people can a restaurant dining room hold?
Article 3.1.17.1 bases the occupant load on the number of persons the area is designed for, but not less than the Table 3.1.17.1 value. For dining, beverage and cafeteria space that value is 1.20 square metres per person. A planned seat count above that raises the load, and a permanent sign stating the design occupant load must then be posted.
Which table sets the number of water closets?
Sentence 3.7.4.3.(4) sends dining rooms, restaurants and cafeterias to Table 3.7.4.3.-D. Sentence 3.7.4.3.(5) sends establishments used primarily for alcoholic beverages with limited or no food service to Table 3.7.4.3.-E, which asks for more fixtures. Pick the one that matches how the space will be licensed and operated.
Do staff need their own washroom?
In a restaurant with more than 40 seats, yes. Sentence 3.7.4.3.(6) calls for separate employee facilities under Table 3.7.4.3.-F. With 40 seats or fewer, Sentence 3.7.4.3.(7) lets employees share the patron facilities, and the count uses 50 percent of the seats plus the employees of each sex.
Is the male and female split fixed at half and half?
Sentence 3.7.4.2.(3) assumes the load is divided equally between males and females unless the proportion expected can be determined with reasonable accuracy. The split is an input here.
Can one washroom serve both sexes?
Sentence 3.7.4.2.(10) allows a single water closet for both sexes where the occupant load is not more than 10 persons in an assembly occupancy such as a small restaurant. Sentences 3.7.4.2.(8) and (9) also allow a universal washroom to count toward the fixtures in some cases.
Does this cover accessible washrooms?
It shows how many barrier-free water closet stalls each washroom needs (Table 3.8.2.3.-B) and the minimum number of universal washrooms for the building (Table 3.8.2.3.-A). Use the accessible washroom clearance checker to test the stall and room dimensions.