Free planning tool
Accessible Washroom Clearance Checker
Choose the kind of accessible washroom, enter the clear dimensions you have, and see a pass or fail for each one against the Ontario Building Code minimum.
Preliminary clearance check only. The architect, the accessibility consultant and the building official govern. A pass here does not mean a washroom is compliant.
Enter a measurement
| Item | Code minimum | Entered | Result |
|---|
Ardenvale carries out AODA accessibility retrofits and washroom renovations for offices, shops, restaurants and condominium common areas across the Greater Toronto Area.
Get a quote for your accessible washroomUse this tool from any AI assistant
Paste this link into ChatGPT, Claude, Gemini, Copilot, Perplexity or any AI assistant and ask it to read the result:
Change the numbers in the link to match your project. All tools for AI assistants.
Sources and assumptions
- Last checked 2026-11-09, against the 2024 Building Code Compendium and the e-Laws text of Ontario Regulation 191/11.
- 2024 Ontario Building Code (O. Reg. 163/24), Division B, Subsection 3.8.3 Sentences 3.8.3.3.(1) and (6); 3.8.3.8.(1), (2) and (10); 3.8.3.9.(1); 3.8.3.11.(1); 3.8.3.12.(1), (3) and (6). Projects permitted under the earlier Ontario Regulation 332/12 may be subject to that version.
- Integrated Accessibility Standards Regulation (O. Reg. 191/11), section 80.21 Subsection 80.21(2): the exterior paths of travel requirements do not apply to paths of travel regulated under the Building Code.
- Dimensions used Stall: turning space 1,500 mm; front clear space 1,500 mm; door 850 mm; centre line 460 to 480 mm; transfer space 900 mm by 1,500 mm; seat 430 to 485 mm; 1,700 mm to an in-swinging washroom door; 1,400 mm to a wall-mounted fixture. Ambulatory stall: depth at least 1,500 mm, width 890 to 940 mm, door 810 mm. Universal washroom: 1,700 mm each way, 850 mm door with power operator, latch 900 to 1,000 mm, change table space 810 mm by 1,830 mm. Lavatory: rim not over 865 mm, 735 mm clearance at the front edge.
Upgrading an accessible washroom?
Send us the plans or a short description. We will arrange a site review and return a clear written quote.
Ardenvale carries out AODA accessibility retrofits and washroom renovations for offices, shops, restaurants and condominium common areas across the Greater Toronto Area. AODA accessibility retrofits · Washroom renovation
Frequently asked questions
What does this checker test?
Clear dimensions you measure or read from the drawings, against the minimums in Ontario Building Code Articles 3.8.3.8 (barrier-free and ambulatory water closet stalls), 3.8.3.9 (water closet seat height), 3.8.3.11 (lavatories) and 3.8.3.12 (universal washrooms). Any measurement you leave blank is shown as not entered and is not counted as a pass.
What clear space does a barrier-free stall need?
Sentence 3.8.3.8.(1) calls for a clear turning space of at least 1,500 mm in diameter inside the stall, a clear floor space of at least 1,500 mm in diameter in front of it, and a door with a clear opening of at least 850 mm. The door swings outward unless an 820 mm by 1,440 mm clear floor area is provided inside the stall.
How is the water closet placed in the stall?
Sentence 3.8.3.8.(2): the centre line of the water closet is 460 mm to 480 mm from one side wall with a clear transfer space at least 900 mm wide and 1,500 mm deep on the other side, or a transfer space of that size on each side. The seat is 430 mm to 485 mm above the floor (Sentence 3.8.3.9.(1)).
How big is a universal washroom?
Sentence 3.8.3.12.(1) allows no internal dimension between walls under 1,700 mm and requires room for a wheelchair to turn in an open space of at least 1,700 mm in diameter, a power door operator, and a clear space at least 810 mm wide and 1,830 mm long for an adult-size change table. Sentence 3.8.3.12.(6) exempts some small suites from the change table space.
What about the Accessibility for Ontarians with Disabilities Act?
Section 80.21(2) of Ontario Regulation 191/11 says the exterior paths part of the accessible built-environment standard does not apply to paths regulated under the Building Code, so inside a building the Building Code dimensions in this tool govern. Other duties under the Act, such as customer service and employment, are separate.
Does a pass mean the washroom is compliant?
No. This is a planning check of clear dimensions only. Grab bars, flush controls, mirrors, accessories, signs, door hardware, the barrier-free path to the washroom and the number of accessible washrooms a building needs also apply, and the building official makes the call.
Cite this tool
Copy this HTML to link to the tool from your own page or document.